Product #: G1701CA |
Contained InG1710CA
Data Analysis
G1711CA Additional User license (G1701CA) G1712CA Additional User license (G1710CA) G1617CA Upgrade (G1701CA) G1618CA Upgrade (G1710CA) G1717CA Data Analysis/ PC Bundle |
|
Revision #: C.00.00/ 01 |
|
|
Release Date: circa 12/1999 |
|
The G1701CA MSD Chemstation software was a major revision. Many aspects of the software had been enhanced. This includes changes to data analysis, reporting, and control of instruments. The most notable change was the introduction of LAN as the instrument control protocol, replacing HP-IB, and supporting the new 5973N LAN based MSD. Shortly after the release of C.00.00, a C.00.01 update was released to fix some defects. Although some backward compatibility with existing hardware is still possible, some older instruments and accessories have been dropped. Revision C.00.01 did add support for a new HP-IB card and software driver for that card. If you are current user of the MSD Chemstation and your hardware is supported, this revision is a solid replacement.
Instrument
Control:
1.
LAN
instrument interface replaces previous HP-IB and eliminates the distance
limitations with Chemstations.
2.
LAN
instrument control and the new 5973N MSD made it possible to control up to 2 GC/MSDs
simultaneously.
3.
Software
functionality to communicate with the 5973N Local Control Panel.
Software: (Supported
in Enhanced, Environmental, and Reformulated Gas data analysis modes unless
otherwise noted)
1.
Auto-Quant
setup provides a fast, simple, and step-by-step process for creating a standard
calibration.
2.
New
process for calculating and reporting signal-to-noise values (Enhanced data
analysis mode only).
3.
DoList
function is configurable by user for manual and automated data reprocessing
(replaced Reprocess Sequence).
4.
Data
file export of three-dimensional MS data for use in third party applications.
5.
Retention
Time Locking (RTL) has a “closed” loop functionality that allows automated
analysis to automatically update retention times do to normal operational
drift.
6.
Sample
work list may now be imported as a TAB or CSV separated file, automation
sequence created, and sequence verified by simulation.
7.
Secured
Mode is now more sample centric by allowing the use of up to 15 sample names per
method.
8.
Instrument
control includes specific system performance parameters with limits that may be
set by the operator (I.e., limit on the number of injections).
9.
Drug
analysis mode only:
·
Save
MSD tune and audit trail parameters.
·
Chromatographic
quality checks (resolution, tailing, symmetry, and signal-to-noise).
·
New
batch summary report.
·
User
defined criteria for real-time decisions during batch sequencing.
10.
New
summary report for screening pesticides using the RTL functionality (Enhanced
data analysis mode only).
|
MS/ Smart Card: |
5972-Smart Card2 (with patch), 5973-Smart Card 2
plus, 7973N Smart Card 3 |
|
GCs: |
5890 series (HP-IB) , 6890 and 6890 Plus (LAN or
HP-IB) |
|
GC Detectors: |
FID, TCD, NPD, uECD, ECD, FPD, single wavelength FPD |
|
Accessories: |
Purge/ Trap(1), Headspace(1),
ALS (18594B, G1512A, and G2612A
controllers; 18593B, G1513A, and G1613A injectors), Analog Digital Converter 35900C/E. (1) Supported in a remote start mode only. |
|
Interfaces/ Software
Drivers: |
C.00.00: LAN,
HP-IB (82335C , G.02.02 driver) C.00.01 LAN, HP-IB (82341C, G.02.02 driver), (82350A,
J.01.00 driver) |
|
Software: |
Carbon Copy®, Excel™ 4/5 |
|
MS Libraries: |
G1033A NIST bundle, G1043A NIST98, G1044A NIST98,
G1041A NIST98 upgrade, G1034A Wiley, G1036A NIST Structures, G1038A Stan
Pesticides, and G1039B Pfleger Drugs |
|
Media: |
CD-ROM |
|
Operating System: |
Windows NT™ 4.0 SP4 [C.00.00] Windows NT 4.0 SP6 [C.00.01] |
|
PC (minimum): |
266 mhz, 64mb RAM |
|
Printer: |
LaserJet™ 4000, 6P |